Warning! All electrical connections must
be made by a qualified electrician.
Caution! Do not drill or solder the wire
ends. This is strictly forbidden!
Caution! Do not connect the cable
without cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from black and
brown wires.
2. Remove an insulation of the brown and black cable
ends.
3. Apply a new wire end sleeve of 1.5 mm² on each
cable end. (special tool required).
Cable cross section
N
L1
N
L
230V~ 400V 2~N
L2
One-phase connection - 230 V~ Two-phase connection - 400 V 2 ~ N
Green - yellow Green - yellow
N Blue and blue Blue and blue N
L Black and brown Black L1
Brown L2